1What your device needs Voltage drop
35 mm²
95 % of allowed drop
At most 2 % drop (0.214 V) at 206 A: calculated 33.13 mm², rounded up to 35 mm².
Enter what you connect and how the cable runs. You instantly get cable size and fuse, calculated as in vehicle engineering: not just by voltage drop, but also by heat and installation.
Some inputs were invalid and have been replaced.
35 mm²
95 % of allowed drop
At most 2 % drop (0.214 V) at 206 A: calculated 33.13 mm², rounded up to 35 mm².
70 mm² ↑ thicker✓ fine
35 mm²: 149 % load
At 50 °C, 35 mm² would run at 149 % with 167 A. Only 70 mm² carries that continuously (96 %).
70 mm² ↑ thicker✓ fine
70 mm²: 96 % load
Free, with spacing, devices in the bundle: 1, factor 1. 70 mm² runs at 96 %: fine.
MEGA 300 A
none fits
In the fuse box at 65 °C it must hold 200 A continuously: MEGA 300 A (holds 205 A there). It protects the cable against short circuit, but not fully against overload: the cable carries 174 A. That is fine if the device limits its own current, like an inverter, charger or DC-DC charger. For distribution or sockets, split the circuit.
Only for DC in vehicles (12, 24, 48 V). Not for 230 V: shore power and inverter output belong in the hands of a qualified electrician.
Lugs, crimps, fuse holders and switches must handle the same current. Most hot cables are really hot connections.
A = L × I ÷ (κ × ΔU) = 2 × 206 ÷ (58 × 0.214) = 33.13 mm², rounded up 35 mm²
| Cross-section | at 30 °C | at 50 °C | Resistance |
|---|---|---|---|
| 0.5 mm² | 11 A | 7.8 A | 37.1 mΩ/m |
| 0.75 mm² | 15 A | 10.6 A | 24.7 mΩ/m |
| 1 mm² | 19 A | 13.5 A | 18.5 mΩ/m |
| 1.5 mm² | 24 A | 17 A | 12.7 mΩ/m |
| 2.5 mm² | 32 A | 22.7 A | 7.6 mΩ/m |
| 4 mm² | 42 A | 29.8 A | 4.71 mΩ/m |
| 6 mm² | 54 A | 38.3 A | 3.14 mΩ/m |
| 10 mm² | 73 A | 51.8 A | 1.82 mΩ/m |
| 16 mm² | 98 A | 69.6 A | 1.16 mΩ/m |
| 25 mm² | 129 A | 91.6 A | 0.743 mΩ/m |
| 35 mm² | 158 A | 112 A | 0.527 mΩ/m |
| 50 mm² | 198 A | 140 A | 0.368 mΩ/m |
| 70 mm² | 245 A | 174 A | 0.259 mΩ/m |
| 95 mm² | 292 A | 207 A | 0.196 mΩ/m |
| 120 mm² | 344 A | 244 A | 0.153 mΩ/m |
| Devices | Bundled or in trunking | Side by side on wall or floor | Free, with spacing | Under the ceiling, touching | Under the ceiling, spaced |
|---|---|---|---|---|---|
| 1 | 1 | 1 | 1 | 0.95 | 0.95 |
| 2 | 0.8 | 0.85 | 0.94 | 0.81 | 0.85 |
| 3 | 0.7 | 0.79 | 0.9 | 0.72 | 0.85 |
| 4 | 0.65 | 0.75 | 0.9 | 0.68 | 0.85 |
| 5 | 0.6 | 0.73 | 0.9 | 0.66 | 0.85 |
| 6 | 0.57 | 0.72 | 0.9 | 0.64 | 0.85 |
| 7 | 0.54 | 0.72 | 0.9 | 0.63 | 0.85 |
| 8 | 0.52 | 0.71 | 0.9 | 0.62 | 0.85 |
| 9 | 0.5 | 0.7 | 0.9 | 0.61 | 0.85 |
| 10 | 0.48 | 0.7 | 0.9 | 0.61 | 0.85 |
| 12 | 0.45 | 0.7 | 0.9 | 0.61 | 0.85 |
| 14 | 0.43 | 0.7 | 0.9 | 0.61 | 0.85 |
| 16 | 0.41 | 0.7 | 0.9 | 0.61 | 0.85 |
| 18 | 0.39 | 0.7 | 0.9 | 0.61 | 0.85 |
| 20 | 0.38 | 0.7 | 0.9 | 0.61 | 0.85 |
| Devices | Bundled or in trunking | Side by side on wall or floor | Free, with spacing | Under the ceiling, touching | Under the ceiling, spaced |
|---|---|---|---|---|---|
| 1 | 70 | 70 | 70 | 95 | 95 |
| 2 | 120 | 95 | 95 | 95 | 95 |
| 3 | 120 | 120 | 95 | 120 | 95 |
| 4 | > 120 | 120 | 95 | > 120 | 95 |
| 5 | > 120 | 120 | 95 | > 120 | 95 |
| 6 | > 120 | 120 | 95 | > 120 | 95 |
| 7 | > 120 | 120 | 95 | > 120 | 95 |
| 8 | > 120 | 120 | 95 | > 120 | 95 |
| 9 | > 120 | 120 | 95 | > 120 | 95 |
| 10 | > 120 | 120 | 95 | > 120 | 95 |
| 12 | > 120 | 120 | 95 | > 120 | 95 |
| 14 | > 120 | 120 | 95 | > 120 | 95 |
| 16 | > 120 | 120 | 95 | > 120 | 95 |
| 18 | > 120 | 120 | 95 | > 120 | 95 |
| 20 | > 120 | 120 | 95 | > 120 | 95 |
| Type | Rating | holds at 65 °C | protects the cable |
|---|---|---|---|
| Blade fuse (ATO) | – A | – A | ✓ yesshort circuit only |
| MIDI | – A | – A | ✓ yesshort circuit only |
| MEGA | 300 A | 205 A | ✓ yesshort circuit only |
Why is voltage drop not enough? Current heats every cable. Above a certain current it gets hotter than its insulation can take continuously, however short it is. Short, thick inverter cables slip through the voltage-drop check and fail on heat.
Why 10.7 V instead of 12 V? For voltage drop the worst moment counts: an almost empty battery. There a device draws the most current for the same power, and most 12 V low-voltage cut-offs switch off around 10.7 V. For heat and fuse, the continuous current at nominal voltage counts instead.
Why a 10 % margin? No device is lossless. An inverter with 1,000 W output draws about 1,050 to 1,100 W from the battery. The margin covers efficiency and disturbances.
Why 2 or 4 %? Chargers, controllers, inverters and electronics need an accurate voltage or they cut out early or charge wrongly: 2 %. Lights, pumps and fans tolerate 4 %.
Why double length? Current flows out and back. If the device is 3 m from the battery, that is 6 m of cable. Only with the negative via the chassis does the positive cable count alone.
What is 58? The conductivity of copper in m/(Ω·mm²). Fine-stranded cable has slightly higher resistance; the cross-check shows the margin covers it.
Why 50 °C? A vehicle stands in the summer sun; under the roof, floor and panels it gets hot. At 50 °C a PVC-insulated cable carries only 71 % of what it carries at 30 °C. For cables with a higher temperature class the values are on the safe side.
What does installation mean? A cable sheds heat through its surface. Free with spacing that works well; in a bundle, corrugated tube or closed trunking, cables heat each other. So a cable may carry less current there. Engineers call this grouping.
What counts? Every device whose cables run in the same bundle and draw current at the same time. Positive and negative of one device count as one, so does a multi-core cable. Eight devices in a bundle: each cable may carry only about half (factor 0.52).
What the fuse is for: it protects the cable, not the device. It must hold the continuous current in a hot fuse box, and it should not be larger than what the cable carries, otherwise it only protects against short circuits. Fuses also weaken in heat: a MEGA 300 A holds only 205 A at 65 °C.
DC only: everything here applies to 12, 24 and 48 V circuits in vehicles. 230 V follows other standards, other protective devices (circuit breakers, RCDs) and other tables.
Calculated for 12 V, negative as a cable, cable alone and free, 50 °C. Columns: distance to battery. In a bundle it gets more, the calculator above shows how much.
| Load | Current | 0.5 m | 1 m | 2 m | 3 m | 5 m | Fuse |
|---|---|---|---|---|---|---|---|
| LED light | 0.83 A | 0.5 mm² | 0.5 mm² | 0.5 mm² | 0.5 mm² | 0.5 mm² | Blade fuse (ATO) 1 A |
| tigerexped water pump small (11 l/min) | 8.00 A | 0.75 mm² | 1 mm² | 2.5 mm² | 2.5 mm² | 4 mm² | Blade fuse (ATO) 15 A |
| tigerexped water pump large (18 l/min) | 15.0 A | 1.5 mm² | 1.5 mm² | 4 mm² | 6 mm² | 10 mm² | Blade fuse (ATO) 25 A |
| Roof fan | 3.33 A | 0.5 mm² | 0.5 mm² | 0.75 mm² | 1 mm² | 2.5 mm² | Blade fuse (ATO) 5 A |
| USB-C/USB-A socket TEX4205-EVO | 3.75 A | 0.5 mm² | 0.75 mm² | 1.5 mm² | 2.5 mm² | 4 mm² | Blade fuse (ATO) 7.5 A |
| convertiger 100 (USB-C 100 W) | 8.33 A | 0.75 mm² | 1 mm² | 2.5 mm² | 2.5 mm² | 6 mm² | Blade fuse (ATO) 15 A |
| Compressor fridge | 5.00 A | 0.5 mm² | 1 mm² | 2.5 mm² | 4 mm² | 6 mm² | Blade fuse (ATO) 7.5 A |
| DC-DC charger 30 A | 41.7 A | 10 mm² | 10 mm² | 25 mm² | 25 mm² | 50 mm² | MIDI 70 A |
| Inverter 1000 W | 83.3 A | 25 mm² | 25 mm² | 35 mm² | 50 mm² | 95 mm² | MIDI 125 A |
| Inverter 2000 W | 167 A | 70 mm² | 70 mm² | 70 mm² | 120 mm² | > 120 mm² | MEGA 300 A |
| Inverter 3000 W | 250 A | > 120 mm² | > 120 mm² | > 120 mm² | > 120 mm² | > 120 mm² | none fits |
Run free and close to the battery (up to about 2.1 m): 70 mm² with a 300 A MEGA fuse. In trunking with other devices it quickly becomes 120 mm². At 1 m a voltage-drop-only calculator says 35 mm²; that carries only 112 A continuously at 50 °C, while 167 A are needed.
No. Voltage drop only tells you whether enough voltage reaches the device. Whether the cable can carry the current continuously without overheating is a separate limit: its current rating. For short, high-current cables it almost always decides, and it drops with heat and bundling.
Yes. Current flows out and back, the formula needs the whole path. If the device is 3 m from the battery, calculate with 6 m. Only with the negative via the chassis does the positive cable count alone. Our calculator asks for the one-way distance and doubles it.
The fuse protects the cable, not the device. It must hold the continuous current plus a 20 % safety factor even in a hot fuse box (65 °C) and should not be larger than what the cable carries in its installation. The calculator picks the matching blade (ATO), MIDI or MEGA fuse.
Because fuses weaken in heat. A MEGA 300 A holds only 205 A continuously at 65 °C. Choosing by the printed rating leads to nuisance blowing in summer.
No. It applies to DC (12, 24, 48 V) in vehicles. 230 V AC, i.e. shore power and the inverter output, follows building wiring rules with circuit breakers and RCDs and belongs in the hands of a qualified electrician.
For sensitive devices such as chargers, solar controllers without sense wire and inverters at most 2 %, for lights and pumps up to 4 %. We take the percentage of the lowest voltage, for 12 V that is 10.7 V: 2 % is 0.214 V.
In summer a vehicle heats up a lot, especially under the roof, floor and panels. At 50 °C a PVC-insulated cable carries only 71 % of its 30 °C rating: 1.5 mm² then manages 17 A instead of 24 A.
How the cable runs: free with spacing, side by side on a surface, or bundled in a tube or trunking. The worse it can shed heat, the less current it may carry. Eight devices in a bundle: each cable may carry only 52 %.
Count every device whose cables run in the same bundle and draw current at the same time, yours included. Positive and negative of one device count as one, so does a multi-core cable.
For the same power, 24 V carries only half the current. A 2000 W inverter needs only 25 mm² at 24 V instead of 70 mm². For large inverters 24 V is often the key to manageable cables.
No. Always round up to the next size you can buy. A result of 1.08 mm² means 1.5 mm².
No. CCA is copper-clad aluminium and conducts much worse than copper. Our calculation only applies to copper stranded cable, look for FLRY or FLY.
Usually it is not the cable but a connection: a badly crimped lug, an undersized fuse holder or a loose screw. Every contact point must handle the same current as the cable.
DC only: everything here applies to 12, 24 and 48 V circuits in vehicles. 230 V follows other standards, other protective devices (circuit breakers, RCDs) and other tables.
This calculator is guidance based on our method and does not replace a qualified person. Manufacturer data take precedence. Working on electrical systems requires expertise. All information without guarantee.