Air Ducting
Air Ducting
Bring the warmth from your heater to where you need it. Warm-air ducts, branches and suitable outlets let you heat the living area, sleeping space and other parts of your camper van. Start by choosing the correct system diameter, then plan the duct routes and outlets so air can flow freely.
Which warm-air distribution setup suits your conversion?
Good warm-air distribution starts with the layout: where is the heater installed, which areas need heating, and how can the air reach them? These decisions determine which ducts, branches, connectors and outlets you need.
Our “60 mm system”, “75 mm system” and “90 mm system” subcategories help you choose components with matching connection diameters. However, the complete installation matters: duct lengths, bends, branches and outlets all affect how much air the heater can move.
60, 75 or 90 mm: which diameter do you need?
Start with your heater’s requirements. The Autoterm Air 2D requires warm-air ducting with a diameter of 60 mm, while the Air 4D and the TWIN-Kit require 90 mm. For other heaters, check the relevant installation manual. The 75 mm system is intended for appropriately designed installations and matching components; it is not an interchangeable compromise between 60 and 90 mm.
A smaller duct may be easier to route through tight spaces inside furniture, but it increases airflow resistance. Do not simply reduce the main duct diameter to save space. Even if an adapter physically fits, this does not automatically mean that the reduction is permitted for your heater.
At branches, the downstream ducts and outlets must together allow enough air to pass. Two smaller connections do not automatically replace one larger main connection. Plan transitions according to the intended system layout and the heater’s requirements.
Warm-air ducts: short routes and gentle bends
Choose direct routes with as few changes of direction as possible. Long runs, tight bends and crushed ducts restrict airflow. This can leave distant outlets with little heat or cause the heater to overheat because it cannot release enough heat.
Allow plenty of space immediately after the heater outlet in particular, and follow the specified requirements for straight sections and bend radii. Flexible ducting helps you work around the conversion, but it should not be kinked or routed in unnecessary loops.
Use warm-air ducting suitable for the temperatures produced by the heater. Secure it so it cannot chafe while driving or be crushed by luggage in storage compartments. Alongside the duct diameter, allow room for connectors, clamps and installation access.
Y-piece or T-piece: directing the airflow
Branch fittings distribute warm air to several areas. A Y-piece splits the flow with gentler changes of direction and often offers less resistance than a right-angle branch. A T-piece may suit a particular installation, but it affects airflow distribution differently.
Air does not automatically divide equally between all connected ducts. A short, straight run generally offers less resistance than a long run with several bends. Even a symmetrical Y-piece therefore does not guarantee equal airflow if the downstream routes differ considerably.
Plan the branches so that more distant areas also receive enough warm air. Additional outlets do not increase the heater’s output; they divide the available airflow between more locations.
Outlets: choosing the right position and function
An outlet should direct warmth into the intended area without being blocked by bags, cushions or other items during everyday use. A position close to floor level can help bring heat into the occupied space. Avoid directing hot air straight at sensitive materials or a sleeping area from close range.
Rotating outlets let you adjust the direction of airflow. Closable versions can shut off individual secondary areas when needed. Alongside the duct connection, check the required mounting cut-out, installation depth and any separate connection fittings needed.
The heater must always be able to release enough heat. With Autoterm air heaters, at least one outlet must be non-closable. This permanently open air path must be adequately sized; a small open secondary outlet is not automatically sufficient. The required airflow must still be maintained when other outlets are closed.
Include the air intake in your planning
For warm air to flow out, the heater must be able to draw in enough heating air. If it is installed inside a seat box, for example, the box needs a sufficiently large, unobstructed air path from the interior. A small gap or a grille blocked by luggage can restrict the air supply.
In a recirculating setup, the discharged air must also be able to return to the intake. Allow for closed doors, separate sleeping areas and furniture. Avoid a layout where the heater immediately draws its own hot outlet air back in while the rest of the living space stays cold.
The heating-air intake must not be confused with the combustion-air intake. They serve different purposes and must be planned separately in accordance with the installation requirements.
Hot water tanks and other components in the warm-air path
If you are adding a hot water tank designed for use with an air heater, such as one supplied in a Warmduscher-Kit, include it in the layout from the start. Connection diameters, installation position and the remaining duct routes must suit the intended system.
Every additional component changes airflow resistance and may also affect heat distribution. Check the complete air path rather than simply matching individual connection sizes. This also applies when expanding an existing installation later.
Have these details ready when choosing
- Heater: Which minimum duct diameter and airflow requirements apply to your model?
- Duct routes: What lengths, bends and pass-throughs are needed between the heater and outlets?
- Distribution: Which areas need heat, and how do the routes to them differ?
- Outlets: Which connection and mounting dimensions do you need, and which adequately sized air path will remain permanently open?
- Intake and return airflow: Can the heater draw in air freely and circulate it through the vehicle?
- Additional components: Have you included the hot water tank, adapters, connectors and fixings in the layout?
A well-planned warm-air distribution system helps your heater deliver useful warmth throughout the vehicle. If some areas remain cold, check the air routes and outlets before considering a larger heater.