Error 2 on Autoterm Air / Planar auxiliary heaters
What does Error 2 mean
Error 2 (or 12 x blink on the PU-5 control panel) indicates a defective temperature sensor.
The measured temperature is in ranges that are not actually to be expected, because the heater would already reduce its output earlier (from 30 degrees) to avoid overheating. See also our detailed explanation under Error 1.
The heater regards the sensor as implausible at temperatures in a range of 40 to 50 degrees, and therefore the sensor as defective. As a rule that is then really the case.
Repair
If the temperature sensor is defective, the main board has to be replaced. If the warranty is to be preserved, this repair should be commissioned from an authorized service partner, since replacing this component also changes the serial number of the heater.
If Error 2 does not appear on your display and you only landed on this error page out of interest in the heaters, we have some reassuring news: a defective temperature sensor is extremely rare and almost never happens.